8110585 02 06/09 1 of 4 © COPYRIGHT 1991 HENNESSY INDUSTRIES AND COATS ALL RIGHTS RESERVED PRINTED IN U.S.A.
Pressure Limiter Kit 8110584
Installation Instructions & Parts List
for RC-15A, RC-15AA, RC-20A, RC-20AA
& 40-40 Tire Changers
Hennessy Industries • 1601 J.P. Hennessy Drive, LaVergne, TN 37086-3565 (800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX • www.ammcoats.com
Installation Instructions
Always DISCONNECT THE ELECTRICAL
POWER before servicing equipment. This
prevents electrical shock or accidental
movement of the systems operated by the
electrical power.
Always DISCONNECT AIR SUPPLY before
servicing equipment. This prevents acciden-
tal movement of systems operated by com-
pressed air which may result in personal
injury. BLEED THE AIR SYSTEM by actuating
all the valves.
Before beginning any work, clear the area and position
machine for easy access. Disconnect all power
sources, both air and electricity inputs. Allow any stored
air in the reservoir to escape by depressing the inflate
pedal.
RC-15A and 15AA Pressure Limiter:
1. Remove the side panel.
2. Remove two nuts (ref 1), securing inflation valve
bracket (ref 2) to chassis.
3. Mount pressure limiter bracket (ref 3) to existing
bolts (ref 4) and securely tighten two nuts (ref 1).
4. Install pressure limiter (ref 5) to pressure limiter
bracket (ref 3) using two 1-3/4-inch long bolt (ref 6) and
two nuts (ref 7) provided in kit. Fasten securely.
5. Remove 1/4-inch hose (ref 8) from small valve (ref
9) and connect to port B on pressure limiter (ref 5).
6. Connect 1/4-inch hose 20-inches long (ref 10) sup-
plied in kit to port A on small valve (ref 9) and port A on
pressure limiter (ref 5). Securely tighten using 1/4-inch
hose clamps provided in kit.
7. Check all connections for proper installation and
tightness prior to reconnecting air supply.
8. Check unit for proper operation. Refer to the pres-
sure limiter maintenance section on page 4 of this
instruction.
9. Remove lens cover from
air gauge and install new
decal to gauge as shown in
diagram. Reinstall lens cover.
10. Replace side panel.
11. Review proper tech-
nique and operation with the
operators and supervisors.
CAUTION
CAUTION
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Pressure Limiter Kit 8110584

8110585 02 06/09 1 of 4 © COPYRIGHT 1991 HENNESSY INDUSTRIES AND COATS ALL RIGHTS RESERVED PRINTED IN U.S.A.Pressure Limiter Kit 81105

Page 2

RC-20A and 20AA Pressure Limiter:1. Remove the side panel.2. Mount pressure limiter bracket (ref 1) to inflationbracket (ref 2) using two 1/4-inch bol

Page 3

5. Attach 37-inch long hose (ref5) to pressure limiter port B.Attach quick coupler end toend of 37-inch longhose. Securely fas-ten all clamps.Reattach

Page 4 - Pressure Limiter Maintenance

Pressure Limiter MaintenanceOperating a tire changer with a defective,improperly adjusted, or by-passed pressurelimiter could cause an operator to acc

Comments to this Manuals